Product specifications
HARTING 24054011400: Ha-VIS eCon 3011GBT-AT1-SPE; Industrial Ethernet Switches; Media converter; Full Gigabit Ethernet; Nominal voltage: 24, 48; Total number of ports: 2; 10/100/1000 Mbit/s (RJ45-Ports): 1; 1000 Mbit/s (RJ45-Ports): 1; Operating temperature: -40 ... +70 °C
- Manufacturer
- HARTING
- Manufacturer part number
- 24054011400
- Product type
- Industrial Ethernet Switches
- Pollution degree
- 2
- Operating temperature
- -40 ... +70 °C
- Storage temperature
- -40 ... +85 °C
- Relative humidity
- 0 ... 95 % Non-condensing (operation); 0 ... 95 % Non-condensing (storage/transport)
- Air pressure
- ≥795 hPa ≈ 2000 m
- Degree of protection acc. to IEC 60529
- IP30 mated condition
- Overvoltage category
- II (400 ≤ CTI < 600)
- Total number of ports
- 2
- Fixing
- 35 mm DIN rail acc. to EN 60715
- Switching technology
- Store and Forward
- Frame size
- 10.24 kB
- MAC table size
- 1k Entries
- MAC–address filter
- LLDP and PROFINET PTCP Delay (01-80-C0-00-00-0E) blocked
- Packet buffer size
- 1 Megabit
- Non blocking
- Yes
- Quality of service
- Yes
- Signal contact
- No
- PoE functionality
- No
- Field of application
- Indoor usage
- Jumbo frame support
- Yes
- Pack contents
- Pluggable screw contact for power supply; Assembly instructions
- China RoHS
- e
- RoHS
- compliant
- REACH SVHC substances
- Not contained
- REACH Annex XVII substances
- Not contained
- REACH ANNEX XIV substances
- Not contained
- ELV status
- compliant
- California Proposition 65 substances
- Not contained
- PFAS
- Yes
- PFAS substances
- Fluoroelastomers
- Material (hood/housing)
- Aluminium (anodised); Stainless steel
- Length
- 34 mm
- Width
- 33 mm
- Height
- 130 mm
- EtherNet/IP
- No
- PROFINET
- Yes
- FCC
- Yes
- Approvals
- CE; on request
- Specifications
- EN 55032 emission standard; EN 55035 EMC Interference immunity; EN 61000-4-2 Electrostatic discharge (ESD); EN 61000-4-3 Electromagnetic field; EN 61000-4-4 Rapid transients (burst); EN 61000-4-5 Surge voltages; EN 61000-4-6 conducted disturbances; EN 61000-6-4 emission standard; IEC 60068-2-6 Vibration (sinusoidal)
- Identification
- Single Pair Ethernet (SPE)