HARTING

HARTING 97000001548

Industrial Ethernet Switches · Industrial communication

Product specifications

HARTING 97000001548: Ha-VIS eCon 4080BT_SW_BT_P; Industrial Ethernet Switches; Unmanaged; Fast Ethernet; Nominal voltage: 48, 54; Total number of ports: 8; 10/100 Mbit/s (M12D-Ports): 8 x; Operating temperature: -40 ... +70 °C

Manufacturer
HARTING
Manufacturer part number
97000001548
Product type
Industrial Ethernet Switches
Operating temperature
-40 ... +70 °C
Storage temperature
-40 ... +85 °C
Relative humidity
10 ... 95 % Non-condensing (operation); 10 ... 95 % Non-condensing (storage/transport)
Air pressure
≥795 hPa ≈ 2000 m
Degree of protection acc. to IEC 60529
IP40 mated condition
Overvoltage category
II (protection through double or reinforced insulation)
MTBF
≈ 535,000 h
Total number of ports
8
Fixing
Wall mounting
Switching technology
Store and Forward
Frame size
2.048 kB
MAC table size
2k Entries
Packet buffer size
0.77 Megabit
Non blocking
Yes
Quality of service
Yes
Energie Efficient Ethernet
Yes
Flow control
Off
Signal contact
No
PoE functionality
Yes
Conformal coating of PCB
Yes
Pack contents
Assembly instructions
China RoHS
e
RoHS
compliant
REACH SVHC substances
Not contained
REACH Annex XVII substances
Not contained
REACH ANNEX XIV substances
Not contained
ELV status
compliant
California Proposition 65 substances
Not contained
PFAS
No
Material (hood/housing)
Aluminium
Length
43.85 mm
Width
100 mm
Height
162 mm
EtherNet/IP
No
PROFINET
No
FCC
Yes
Approvals
CE
Specifications
EN 50155 Railway applications; EN 50121-3-2 Railway applications EMC; EN 61000-6-2 EMC Interference immunity; EN 55035 EMC Interference immunity; EN 61000-4-2 Electrostatic discharge (ESD); EN 61000-4-3 Electromagnetic field; EN 61000-4-4 Rapid transients (burst); EN 61000-4-5 Surge voltages; EN 61000-4-6 conducted disturbances; EN 61000-6-4 emission standard; EN 55032 emission standard; IEC 60721-3 Mechanical stability; IEC 60068-2-6 Vibration (sinusoidal); IEC 60068-2-27 Shock; IEEE 802.3
Element
Industrial Ethernet Switches
Specification
Unmanaged

Include in your enquiry

  • Exact part number, version and required quantity
  • Existing equipment and compatibility requirements
  • Delivery destination and target date

Confirm the required version and compatibility before ordering. Your quotation will specify the proposed equipment and commercial terms.

Browse HARTING products